I   HOME PAGE    I

 
  Welding Technique

Hot Air Welding Sarnafil - Waterproofing - Chicago City Hall, Chicago, USA

The most common technique used to join PVC waterproofing sheets.

The sheets should overlap by at least 50 mm.


The Leister Triac hand welder is used for Hot Air welding of INSUWRAP PVC membranes.

The hand welder is supplied with a 20mm, 40mm, wide welding nozzles and 40mm wide leister rubber roller.

Welding The Lower Seam Edge
Before the seams are welded, they are tag-welded every 2-3m, which ensures uniform seam overlap, welding is then carried out in two passes, during the first pass the lower seam edge only is welded to prevent the hot air from escaping during the actual welding pass.


Sarnafil - Waterproofing - Chicago City Hall, Chicago, USA
Sarnafil - Waterproofing - Chicago City Hall, Chicago, USA Welding The Seam
As per the hot air is being applied, the seam must at the same time be rolled flat to the membrane edge using the pressure roller.
 
External Corner

Round off the corner piece.


Fit in corner piece and tag-weld in to corner.


Complete corner weld.

 

Sarnafil - Waterproofing - Chicago City Hall, Chicago, USA

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
|