I   HOME PAGE    I

 
Covered roofing TANKING

Exposed roofing TUNNEL LINING

DRINKING WATER TANKS

DAMS

SWIMMING POOLS

LANDSCAPE

 

 

TUNNEL LINING

 
SYSTEM DETAILS     DATA SHEET    PROJECTS 

 

Insuwrap PVC underground waterproofing 2000 TNL is a calendered high polymer waterproofing membrane, (thickness 2.0 mm) not compatible with bitumen, manufactured to the highest International standards offering high physical properties and long term durability. Insuwrap 2000 TNL is manufactured using the best raw materials produced by SABIC


 

 
 

 

Test

Standards

STANDARD Requirements

Results, 2000
TNL

Membrane Thickness (mm)

DIN 16938

+10%

2.00

Tensile Strength

DIN 16938

>15N/mm2 longitudinal transversal

>17.90 N/mm2
>17.40 N/mm2

Elongation

DIN 16938
DIN 16730

>200% longitudinal transversal

>400both direction

Thermal Stability

DIN 16938

6hr/80c  <2% longitudinal transversal

<1.0% both direction

Tear Strength (N)

DIN 16730

80 N

>110N

Thermal Ageing

DIN 16938

7d/80 change of tensile
strength & elongation<±20%
folding in cold
at -20c: No cracks

<1% both direction -30c
no cracks

Slit Pressure Resistance

SIA 280/4

1h /5bar (0.5N/mm2) tight

passed

Thermal Ageing 

SIA 280/7

70d/70c mass decrease
<2%
Change of elongation

mass decrease <0.5%Change of elongation <2%
Both Direction

Roots Resistance

SIA 280/10

no root penetration
ingrown roots must die off

passed

Combustibility

SIA 280/11

class V/smoke class2

Passed

Water Vapor Defusion Resistance

DIN16730

Less than 30,000

Less than 21,000

Water Absorption

SIA 280/12

 8 months storage in water <±6% folding in  cold at-20c no cracks

passed

Compression Strength

SIA 280/13

48h/7N/mm2 tight

passed

Puncture resistance

DIN 16730

drop hammer 500gms,  no leak on falling from 750mms

passed

Seam Strength

SIA 280/15

 No peeling or sliding of welded seam

passed

Cold bend

DIN 16730

No cracks at -20c

No cracks at -30c

Resistance to Algea & Rot

DIN 16730

High resistance

High Resistance

Chemical Resistance

DIN 16938

28/lime milk, change of tensile strength longitudinal /transversal %change of elongation <±20% longitudinal/transversal %

Resistance to 10% Calcium Hydroxide, 7 days no change in color, 0.5% change in weight, change in tensile & elongation <3%

 

 

28d/salt water, change of tensile strength longitudinal/transversal change of elongation<±20% longitudinal /transversal %

Resistance of 10% sodium chloride, slight colour change, change in tensile strength & elongation <3%

 

 

28d/sulfurous acid, change of tensile strength longitudinal/transversal % change of elongation<±20% longitudinal /transversal %

 3% sulfuric acid, slight change in colour change in tensile strength & elongation <3%

 

 

Folding in cold at -20c, no cracks in all cases

Pass

 

 

Soil Resistance

Pass

 

 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
|
Covered Roofing | Exposed Roofing | DRINKING WATER TANKS |
|
SWIMMING POOLS | TANKING  | TUNNEL LINING  |  DAMS LANDSCAPE |

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


All Rights Reserved for Insuwrap - Copyright © 2006