4.Horizontal
Application
Apply one layer of Insuwrap PVC
waterproofing membrane.
reinforced with polyester
mesh & ultra violet resistant ( WMR-UV). This membrane will be fixed by
means of mechanical fixation using
aluminum or GI metal strips (30mm wide).
These strips will be fixed by mechanical
fasteners at 40cm spacing on top of the
overlapping joints. Then these joints
are welded by hot air welding machine
and the overlapping will be 50mm
minimum. Special metal screws and
washers with spacing 300mm on the
overlaps can be used instead of holding metal
screws.

5.
Vertical Application
Apply Insuwrap PVC 1500
WMR-UV (1.50 mm thickness) membrane
reinforced with high tenacity
polyester mesh, Ultra violet resistant.
This membrane will be fully adhered by
Insurbond 106 or equivalent to parapet
wall up to 30cm height and the bottom
portion of this membrane will be
properly dressed to the gutter & drains,
PVC coated metal angles will be fixed on
the junctions of horizontal membrane and
gutter. A double layer of the membrane
will be welded by hot air welding on
that angle.

|
6.
Aluminum
Flashing
Install aluminum flashing at the top
edge of the PVC membranes. The flashing
will be fixed with fasteners, then the
upper bend is filled with sealant

|
|

Mechanical Fixation Detail

Perimeter Termination Detail |
|


Conventional System
PVC waterproofing system can be applied
exposed above thermal insulation or
tiles which is very useful in reroofing
cases.

Expansion Joint ( Precast Roofs) 
 |
| |
Drawing Key
1- Main
Steel Frame
2- Corrugated Metal Sheet
3- Plywood (9mm thick), if needed,
maybe covered with polyethylene
separation layer
4- Insuwrap PVC 1500 WMR UV, 1.5mm
thick, reinforced with high tenacity
polyester mesh & ultra violet resistant
5- PVC coated Metal angle ( 50mm x 50mm
)
6- Hot air welding
7- Gutter
8- Insuwrap PVC 1500WMR UV, 1.5mm thick,
reinforced with high tenacity polyester
mesh & Ultra violet resistant, fully
bonded
9- Aluminum Flashing
10- Insurbond 106 contact adhesive or
equivalent
11-Sealant
12- Aluminum Holding Strip
|
|
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
|
Covered Roofing
|
Exposed Roofing
|
DRINKING
WATER TANKS
|
|
SWIMMING POOLS
|
TANKING
|
TUNNEL LINING
|
DAMS
|
LANDSCAPE
|
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
|
|