Insuwrap 1500WMR-UV is a Calendered high polymer waterproofing membrane, (thickness 1.50mm) reinforced with polyester mesh, ultra violet resistant, not compatible with bitumen, manufactured to the highest International standards offering high physical properties and long term durability. Insuwrap 1500 WMR-UV is manufactured using the best raw materials produced by SABIC.
Other available products: Insuwrap PVC 1200WMR-UV, 2000WMR-UV.

 
 

 

Test
 

ASTM  D4434 Results,
 1500 WMR- UV
STANDARD Requirements
Overall thickness of PVC sheet, min, mm 1.5  
Tensile strength at break, min, MPa (psi):    
Machine direction 10.4 (1500) >13.0 (1875)
Cross-machine direction 10.4 (1500) >13.0 (1875)
Elongation at break, min, %    
Machine direction 250 >300
Cross-machine direction 220 >300
Seam Strength, min, % of tensile or breaking strength 75 >82
Retention of properties after heat aging:    
Tensile strength, min,  % of Original 90 >90%
Elongation, min, % of Original 90 >90%
Tear resistance, min, N (bf) 45.0 (10.0) >65
Low temperature ben pass pass
Accelerated weathering test:    
Cracking (7 x magnification ) none none
Crazing ( 7 x magnification ) none none
Linear dimensional change, max, % 0.1 <0.07
Change in weight after immersion in water, max, % ±3.0 <±1.0
Static Puncture Resistance Pass Pass
Dynamic Puncture Resistance Pass Pass
Fire Class ASTM E108 pass (class B)
Accelerated Weathering test ASTM G26 5000 hrs

 
Test DIN 16735 STANDARD Results,
1500 WMR - UV
Requirements
Thickness (mm)   1.5
Mass (kg/m2)   1.96
Tensile strength (N/mm2) Min 8.0 N/mm2 >12.0
Elongation at break Min 150% >300%
Thermal stability (6hrs - 90°c) Less than 1 % <0.1%
Tear Strength (N) Min 80 N >100N
Puncture resistance Drop hammer 500gms, from 300mm no leak Passed
Water vapour defusion resistance (u) Less than 30,000 <22,000
Cold Bend No cracks at - 20°c No cracks at - 30°c
Resistance to Algae & rot   High Resistance
Fire class DIN 4102 Pass (Class B2)
Accelerated Weathering test   5000 hrs

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
|